- Home
- ยป
- Our Product Range
- »
- Fire Alarm Accessories
Fire Alarm Accessories

4 Zone CFP Alarm Sense Two Wire Fire Alarm Panel
Minimum Order Quantity | 01 Piece |
Zones | 4 Zones |
Voltage | 230V |
Frequency | 50/60Hz |
Battery Type | VRLA battery |
Quiescent Current | 25mA |
Brand | C-TEC |
Battery Voltage | 12V |
Battery Power | 3.3Ah |
Compliant Switch Mode PSU | Integral 1.5A EN54-4/A2 |
Mains Rated Current | 350mA maximum |
Alarm Voltage | 20-27V |
Dimensions | 380 x 235 x 96 mm (W x H x D) |
Part No | CFP704-2 |
LPCB certified to EN54-2/4, C-TEC's CFP two-wire 4 zone Alarm Sense fire panel is designed to work with Apollo's AlarmSense range of detectors, call points, sounders and visual indicators.
Most conventional fire systems work with two pairs of wires per zone: one pair for detection devices; the other for alarm devices. By using different voltage bands for quiescent and alarm states, AlarmSense components can be connected to the same pair of supply wires. This reliable technology takes all of the complexity out of fire system design, leading to quicker, more flexible installation and around a 20-25% reduction of labour over a standard four wire system.
The CFP704-2 includes four AlarmSense zones, four conventional sounder circuits, class change & alert inputs and on-board fire & fault relays. A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities.
More Information:
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured in the UK.
- Four AlarmSense zone circuits - compatible with Apollo's AlarmSense detectors, call points, sounders and visual indicators.
- Four conventional sounder circuits.
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- 'Class change' and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure - no bezel required.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
16 Zone Fire Alarm Panel
Minimum Order Quantity | 01 Piece |
Zones | 16 Zone |
Frequency | 50/60Hz |
IP Rating | IP30 |
Dimensions | 380 x 235 x 90 mm (W x H x D) |
Weight | 1.75kg (without batteries) |
Operating Temperature | -5 Degree C to +40 Degree C |
Quiescent Current | 25mA |
Brand | C-TEC |
Input Voltage | 230V |
Humidity | 90-95% |
2 Zone Fire Alarm Panel
Zones | Zone wise one man Walk Test Facility. |
Model Name/Number | (350W X 250H X 100D) |
Fire Alarm Panel 4 Zone
8 Zone Fire Alarm Panel
Conventional Multi Detector
Usage/Application | Fire Alarm System |
Certification | UL listed |
Voltage | 9 ~ 33V DC |
Alarm Current | 40 mA (Max) |
Weight | 130g with base |
Operating Humidity | 0 - 95% RH, non-condensing |
Relative Humidity | 0 - 95% RH, non-condensing |
Sensitivity Range | (1.9 +- 0.76) % / ft |
Operating Voltage | 9 ~ 33V DC |
Operating Temperature | -10 C to 37.8 C |
Diameter | 100 mm dia |
Ip Rating | IP - 42 |
Smoke Sensitivity | (1.9 +- 0.76) % / ft |
FEATURES:
UL Approved
Dual LED’s for 360 visibility
Advanced detection and communication protocol
Easy installation and maintenance
Sleek low-profile housing design
Regular 100mm base.
Sounder (Hooter)
Material | ABS |
Color | RED |
Voltage | 24V DC |
Mounting Type | Surface / Flush Mount |
Alarm Type | Piezo Electric Type |
Sound Level | 85dB@1m |
Current | 40mA |
FEATURES
- Slim and Sleek
- Wall or Ceiling mountable
- Mini Horn with BackBox
- 24VDC Operation
- They are used in Fire, Burglar & Emergency Alarm System.
Manual Call Point
Usage/Application | Fire Alarm System |
Color | Green / Yellow / Red |
Working Voltage | 24VDC |
Working Current | 30mA |
Dimensions Mm | 86 X 86 X 50 mm |
Operating Current | 30mA |
Material | PLASTIC |
FEATURES:
- Alarm status is indicated By Red colour LED.
- Operates on 24 VDC.
- Green Colored for Emergency Release.
- Yellow Colored for Abort.
- 1 No’s of CO & NC Output (Optional).
Agni Emergency Exit Light
Minimum Order Quantity | 1 Piece |
Lighting Type | LED |
Usage/Application | Industrial |
Brand | Agni |
Battery | 2x7.5 Ah |
AC Voltage | 230V |
Frequency | 50/60 Hz |
- Automatic on in case of Power Failure Battery over, under Charge Protection.
Response Indicator
Color | IVORY |
Material | METAL |
Voltage | 12 VDC |
Alarm Current | 10mA |
Alarm Indication | RED LED |
FEATURES:
Compatible for 2 wire detectors.
Operates on 12 VDC.
Alarm status is indicated By Red colour LED.
Dual LED’s for 360 visibility
Flush / Ceiling wall mount